Power Factor Inc. - 800-706-7009 www.powerfactorincdirect.com |
|
Find the battery you want at the right price @ batteries asap!
A+ Rating with the Better Business Bureau
|
Power Factor Inc. is an Eaton Powerware authorized reseller. For information, quote, or to order the Powerware 9120 UPS call us at 800-706-7009.Click here for replacement batteries at our new online store batteriesasap.com Quick turnaround on quotes, Competitive pricing, Fast delivery and Great Customer service!
Powerware 9120 UPS
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| The
Powerware 9120 UPS provides maximum
power quality and backup power
protection in the 700 - 3000 VA range
and is the ideal power management
solution for networks, Web servers and
telecommunications equipment.
While offering basic surge protection and backup power, the Powerware 9120 UPS additionally offers the best UPS power protection against all nine common power quality problems. |
|||||||||||||||||
|
|||||||||||||||||
|
||||||||||||||||||||||||||||||
Electrical Input |
|
| Nominal Voltage | 120 Vac and 230 Vac; Model Selection Guide for user-selectable voltages |
| Input Voltage Range |
120V: 80 –144 Vac 230V: 120/140/160-276 Vactd> |
| Input Power Factor | >.95% |
| Operating Frequency | 50/60 Hz, Auto-sensing |
| Frequency Range | 45 - 65 Hz |
| Input Protection | Fuse or circuit breaker |
Electrical Output |
|
| On Utility Voltage Regulation | +/-2% of nominal |
| On Battery Voltage Regulation | +/-3% of nominal |
| Nominal Output Voltage | Same as selected input voltage |
| Output Voltage Waveform | Sine Wave |
| Output Voltage Distortion | <3%THD |
| Output protection | Electronic overload sensing, and circuit breaker protection |
| Efficiency |
Online Mode:>86%; Hi-Efficiency Mode:>90% |
Battery |
|
| Internal Battery type | Sealed, lead-acid; maintenance free |
| EBM Battery Type | Sealed, lead-acid; maintenance free |
| On Battery Runtime | See Battery Runtimes |
| Battery Replacement | Hot-swappable internal and external batteries |
| Recharge Time | <4 hours to 90%capacity |
| Start-On-Battery | Allows start of UPS without utility input |
Communications |
|
| User Interface | LCD status screen |
| Audible Alarms |
UPS alarm conditions, including: On-Battery, Low Battery, Overload, UPS Fault |
| Network transient Protector |
In and out jack for all models. UL497A tested |
| REPO Port | Meets NEC code 645-11 intent and UL requirements |
| Communications | One RS232 Serial Port; One Communications Slot; One USB Port |
| Communications cable | 6-foot communications cable included |
| Power Management Software | Powerware Software Suite CD |
General |
|
| Topology | True online, double-conversion |
| Diagnostics | Full system self-test on power up |
| UPS Bypass | Automatic on Overload or UPS failure <4ms |
| Transfer Time to battery | 0 ms |
| Dimensions and Weights | See Model Selection Guide |
| Overload Capacity |
125% for 10 minutes before transfer
to bypass; 150% for 10 seconds before transfer to bypass |
Environmental and Safety |
|
| Safety Certifications | UL1778;cUL22.2 NO.107.1 |
| EMI Compliance |
FCC Part 15, Class B (700-1500),
Class A (2000-3000) 230 V, EN 50091-2 Class B (700-1500), Class A (2000-3000) |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Storage Temperature | -15°C to 50°C (5°F to 122°F) |
| Storage Temperature | 0°C to 25°C (32°F to 77°F) |
| Relative Humidity | 0%to 95%non-condensing |
| Immunity |
EEE C62.41, IEC 61000-4 -2, -3, -4, -5 |
| Network Transient Protector | UL497A |
| Audible Noise at 1 meter | 700-1000 VA: <45dB;1500 VA <50dB; 2000-3000 <52dB |
| Altitude | 3000m (10,000 ft) without deteriorating |
Note: Due to continuing product improvement programs, specifications are subject to change without notice.
|
Model Number |
Power Out (VA/Watt) |
Input/ Output Voltage (Vac) |
Frequency (Hz)2 |
Input Connection3 |
Output Receptacles4 |
Dimensions (HxWxD) in/mm |
Weight (lb/kg) |
| 120 Vac Models1 | |||||||
| PW9120 700 | 700/490 | 120 | 50/60 | 5-15P | (4) 5-15R |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
29/13.2 |
| PW9120 1000 | 1000/700 | 120 | 50/60 | 5-15P |
(4) 5-15R, (2) 5-20R |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
35.5/16.1 |
| PW9120 1500 | 1500/1050 | 120 | 50/60 | 5-15P |
(4) 5-15R, (2) 5-20R |
10.8 x 6.7 x 17.5/ 275 x 170 x 444 |
46.5/21.1 |
| PW9120 2000 | 2000/1400 | 120 | 50/60 | 5-20P | (6) 5-20R |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
82/37.2 |
| PW9120 3000 | 3000/2100 | 120 | 50/60 | L5-30P |
(4) 5-15R, (2) 5-20R (1) L5-30R |
14.2 x 8.6 x 18.6/ 361 x 271 x x 472 |
89/40.5 |
| PW9120 3000h | 3000/2100 | 120 | 50/60 | Hardwired | Hardwired |
14.2 x 8.6 x 18.6/ 361 x 271 x x 472 |
89/40.5 |
| 208 Vac Models | |||||||
| PW9120 3000B | 3000/2100 | 208 | 50/60 | L6-20P |
(2)L6-15R, (1)L6-20R, (1)L6-30R |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
89/40.5 |
| 230 Vac Models5 | |||||||
| PW9120 700i | 700/490 | 230 | 50/60 | IEC-C14 | (4)IEC-C13 |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
28/12.6 |
| PW9120 1000i | 1000/700 | 230 | 50/60 | IEC-C14 | (4)IEC-C13 |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
34/15.3 |
| PW9120 1500i | 1500/1050 | 230 | 50/60 | IEC-C14 | (4)IEC-C13 |
10.8 x 6.7 x 17.5/ 275 x 170 x 444 |
44/19.8 |
| PW9120 2000i | 2000/1400 | 230 | 50/60 | IEC-C14 |
((4)IEC-C13, (1)IEC-C19 |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
81.6/37 |
| PW9120 3000i | 3000/2100 | 230 | 50/60 | IEC-C20 |
(4)IEC-C13, (1)IEC-C19 |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
85/38.5 |
| Optional Extended Battery Modules (EBMs) | |||||||
| PW9120 BATT 700 | - | - | - |
Standard Connector |
- |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
31/14 |
| PW9120 BATT 1000 | - | - | - |
Standard Connector |
- |
9.6 x 6.2 x 16.2/ 243 x 158 x 412 |
44/20 |
| PW9120 BATT 1500 | - | - | - |
Standard Connector |
- |
10.8 x 6.7 x 17.5/ 275 x 170 x 444 |
57/26 |
| PW9120 BATT 2000 | - | - | - |
Standard Connector |
- |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
110/50 |
| PW9120 BATT 3000 | - | - | - |
Standard Connector |
- |
14.2 x 8.6 x 18.6/ 361 x 217 x 472 |
110/50 |
1 Also user-selectable for 100, 110, and
127 Vac.
2 Automatic frequency selection.
3 120V models have 6-ft. attached line cord.
230 V models have 6-ft. detachable line
cord.
4 Divided into 2 Load Segments (receptacle
groups).
5 Also user-selectable for 220 and 240 Vac
| VA |
Standard Internal Battery |
1 EBM | 2 EBMs | 3 EBMs | 4 EBMs | 5 EBMs |
| 700 | 7/18 | 34/70 | 64/140 | - | - | - |
| 1000 | 7/18 | 36/80 | 66/155 | - | - | - |
| 1500 | 7/18 | 29/67 | 56/130 | - | - | - |
| 2000 | 12/34 | 49/107 | 93/195 | 140/310 | 192/403 | 240/504 |
| 3000 | 6/15 | 30/70 | 57/128 | 87/191 | 120/264 | 148/325 |
| Order Number | Description |
| IPK-0329 | ConnectUPS-BD SNMP/WEB Card |
| 1014018 | AS/400 Relay Card |
Buy batteries on-line and get it fast!
|
Power Factor Inc. / Batteries ASAP! 2526 Manana Suite 102 Dallas, Texas 75220 800-706-7009 Established 1996 While every precaution has been
taken to ensure accuracy and completeness in this literature, Power Factor Inc.
assumes no responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions. Specifications
subject to change without notice. |