Powerware 5125 product image

Powerware 5125 UPS
Features and Benefits

PW5125-1000 05146629-5591 / PW5125-1500 05146632-5591 / PW5125-2200 05146635-5591 / PW5125-2200B 05146636-5591 / PW9125-1000i 05146630-5591 / PW5125-1500i 05146633-5591 / PW5125-2200i 05146637-5591 / PW5125-24V 05146638-5591 / PW5125-48V 05146639-5591

The Powerware 5125 Tower UPS provides advanced backup power and power quality management for PCs, workstations, and servers. Delivering basic surge protection and backup power, the Powerware 5125 UPS additionally offers the best UPS power protection against five of the nine common power quality problems.

Tower configurations only, the Powerware 5125 power protection solution is the most flexible UPS system in the 1-2.2 kVA power range.

Features & Benefits

  ABM UPS battery management system doubles service life and notifies user of the need for UPS battery replacement
  Extended Battery Modules (EBMs) increase UPS battery runtime capability

Product Snapshot

 Power Rating  1000-2200 VA
 Voltage:  100-127 V and 200-240 V
 Frequency:  50/60 Hz auto sensing
 Configuration:  Tower
  ABM UPS battery management system doubles service life and notifies user of the need for UPS battery replacement
  Extended Battery Modules (EBMs) increase UPS battery runtime capability
  Buck and Double Boost UPS voltage regulation enables pure sine wave output
  Load Segment Control (separate receptacle groups) enables scheduled shutdowns and maximum backup power time for critical devices
  Network Transient Protector isolates networks, modems and cables from power surges and spikes
  X-slot option cards extend power management capabilities
  Hot-swappable UPS batteries minimize downtime, and extend backup power time for critical devices
  2400/3000 VA UPS system models increase backup power runtime via hot-swappable electronics and UPS battery module
  Two-in-One UPS rack and tower form factor provides versatility

Warranty

  2-year pro-rated warranty
  $25,000 UPS load protection guarantee (with return of Warranty Card receive 10-year pro-rated warranty)
 
Eaton Logo, links to the Eaton homepage

Powerware 5125 UPS Technical Specs

Electrical Input  1000-2200 VA
Nominal Voltage 120, 208 and 230 Vac;
 See Model Selection Guide for user-selectable voltages
Input Voltage Ranges (for user-selectable voltages) Low voltage: 77-152 V; High voltage: 154-288 V
Operating Frequency 50/60 Hz, Auto-sensing
Frequency Range 46-65 Hz
Electrical Output
On Utility Voltage Regulation -10% to +6% of nominal
On Battery Voltage Regulation  ±5% RMS
Voltage Wave Shape (on battery)  Sine Wave
Output Protection  Short circuit protection
Battery
Battery Type Sealed, lead-acid; maintenance free
Battery Run time  See Battery Run Times Table
Battery Replacement Hot-swappable internal batteries and external batteries modules
Recharge Time <3 hours to 90% usable capacity
Start-On-Battery Allows start of UPS without utility input
General
Diagnostics Full System self-test on power up
UPS Bypass No Bypass, Internal Bypass
Transfer Time 2-4ms typical
Dimensions and Weights  See Model Selection Guide
Overload (normal operation) 110% overload, shutdown after 3 minutes.
 150% overload, shut down 10 cycles
Communications
User Interface Front Control Panel
Audible Alarms For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault
Network Transient Protector  UL 497 A, in/out jacks RJ45 (high voltage models network protection) &
 RJ11  (low voltage models modem protection)
X-Slot Interface  RS-232 Single Serial Card (standard),
other options available: See available Options Chart
Cable 6-foot communications cable included
Power Management Software Powerware Software Suite CD-ROM (bundled with UPS)
Environmental 
Safety Certifications  UL; cUL; NOM; C-Tick; CE mark
EMC Compliance FCC Part 15, EN50091-2, Class A for 2.2 KVA and RM; Class B for 1000 and 1500 VA tower models
Operating Temperature  0 to 40º C (32 to 104º F)
Storage Temperature -15 to 50º C (5 to 122º F)
Relative Humidity 0% to 95% non-condensing
Lightning & Surge Protection  ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5
Surge Energy Rating 480 Joules
Audible Noise Less than 40 dBA typical
 Altitude  3000m (10,000 ft) without derating
Note: Specifications are subject to change without notice due to continuing product improvement programs.

Model Selection Guide

Model
Number1
Power 
Rating (VA/Watt)
Input/
Output Voltage
(Vac)2
Input Connection Output Receptacles4 Dimensions HxWxD (in/mm) Weight (lb/kg)
Tower Models (North America)
PW5125
1000
1000/700 120 5-15P,
6 ft line cord
(6) 5-15R 9.45 x 6.38 x 15.79/
240 x 162 x 401
34.3/15.6
PW5125
1500
1440/1050 120 5-15P,
6 ft line cord
(6) 5-15R 9.84 x 6.38 x 18.39/
250 x 162 x 467
50.7/23.0
PW5125
2200
 1920/1600  120 5-20P,
6 ft line cord
 (6) 5-15R,
(2) 5-20R
9.84 x 8.07 x 19.41/
250 x 205 x 493
68.3/31.0
PW5125
2200b
2080/1600 208 IEC-320-15A,
inlet3
(9) IEC-320-10A
(C13)
9.84 x 8.07 x 19.41/
250 x 205 x 493
68.3/31.0
Tower Models (International)
PW5125
1000i
1000/700 230 IEC-320-10A,
inlet3
(6) IEC-320-10A
(C13)
9.45 x 6.38 x 15.79/
240 x 162 x 401
34.3/15.6
PW5125
1500i
1500/1050 230 IEC-320-10A,
inlet3
(6) IEC-320-10A
(C13)
9.84 x 6.38 x 18.39/
250 x 162 x 467
50.7/23.0
PW5125
2200i
2200/1600  230 IEC-320-10A,
inlet3
(9) IEC-320-10A
(C13)
9.84 x 8.07 x 19.41/
250 x 205 x 493
68.3/31.0

1. 50/60 automatic frequency selection.
2. 120 V models are 110 V, 120 V, 127 V user-selectable. 230 V models are 220 V, 230 V, 240 V user-selectable. 208 V models are 208 V, 220 V, 230 V, 240 V user-selectable.
3. Includes (2) each IEC interconnect cables.
4. 1000-1500 VA models are divided into (2) Load Segments (receptacle groups). 2200-3000 VA models are divided into (3) Load Segments (receptacle groups). 5000/6000VA models are divided into (2) Load Segments.

Powerware 5125 Battery Run Time Chart (in minutes full load/half load)*

VA Standard Internal
Batteries
1 EBM 2 EBMs 3 EBMs 4 EBMs
Tower Models
1000 5/14 25/60 55/170 83/199 109/228
1500 6/17 33/79 63/146 92/174 120/201
2200 5/14 26/60 55/170 81/198 106/224

*Up to 4 EBMs can be connected to 1000-2200 VA models. EBM run times include internal batteries.
Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.

Available Options

Order Number Description
05141562-0091 4-post rackmount kit (1000-3000 VA rackmount models) fits 19-inch racks
05146726-5591 2-post rackmount kit (1000-3000 VA rackmount models) fits 19-inch racks
05146447-5502 Multi-server card
05146508-5501 USB Card
1018460 Relay Card
116750221-001 ConnectUPS Web/SNMP card
103002510-5501 Modbus Card
116750224-001 Environmental Monitoring Probe (EMP)
05146519-001 Powerpass Distribution Module (1000/1500 rackmount models only)
05146401-5501 Power Distribution Unit 250 VA 0U form factor. Side cabinet mount (5000/6000 VA)

ABM Technology Hot Sync Technology PW3105 PW5110 PW5115 PW5115 RM PW5125 PW5125 RM PW9120 PW9125 PW9140 PW9155 PW9170+ Ferrups Ferrups RM BladeUPS PW9315 PW9355

UPS Technology Power Problems UPS Systems XPCC Powerware Minute Man Tripp-Lite Emerson Liebert GE Industrial SLA Batteries CSB MK Battery Powersonic Rhino Universal EnerSys Panasonic Power Patrol Big Beam SENS Legacy GS Gates Hawker C&D Dynasty Power Battery Contact Us Links

Up

 

 

 

Buy batteries on-line and get it fast!

UPS Technology
Power Problems
UPS Systems
XPCC
Powerware
Minute Man
Tripp-Lite
Emerson Liebert
GE Industrial
SLA Batteries
CSB
MK Battery
Powersonic
Rhino
Universal
EnerSys
Panasonic
Power Patrol
Big Beam
SENS
Legacy
GS
Gates Hawker
C&D Dynasty
Power Battery
Contact Us
Links

 

 

 

 

 

 

 

 

 

 

 

 

Home Up UPS Technology Power Problems UPS Systems XPCC Minute Man Tripp-Lite Emerson Liebert GE Industrial SLA Batteries CSB MK Battery Powersonic Rhino Universal EnerSys Panasonic Power Patrol Big Beam SENS Legacy GS Gates Hawker C&D Dynasty Power Battery Contact Us Links

Power Factor Inc. / Batteries ASAP!

2526 Manana Suite 102 Dallas, Texas 75220

800-706-7009

Established 1996

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.