Power Factor Inc. is an Eaton Powerware authorized reseller. For information, quote, or to order the Powerware 5125 UPS call us at 800-706-7009.Click here for replacement batteries at our new online store batteriesasap.com Quick turnaround on quotes, Competitive pricing, Fast delivery and Great Customer service!
Powerware 5125 UPS
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| The
Powerware 5125 Tower UPS provides
advanced backup power and power quality
management for PCs, workstations, and
servers. Delivering basic surge
protection and backup power, the
Powerware 5125 UPS additionally offers
the best UPS power protection against
five of the nine common power quality
problems.
Tower configurations only, the Powerware 5125 power protection solution is the most flexible UPS system in the 1-2.2 kVA power range. |
||||||||||||||||
|
||||||||||||||||
|
||||||||||||||||||||||||
| Electrical Input | 1000-2200 VA |
| Nominal Voltage | 120, 208
and 230 Vac; See Model Selection Guide for user-selectable voltages |
| Input Voltage Ranges (for user-selectable voltages) | Low voltage: 77-152 V; High voltage: 154-288 V |
| Operating Frequency | 50/60 Hz, Auto-sensing |
| Frequency Range | 46-65 Hz |
| Electrical Output | |
| On Utility Voltage Regulation | -10% to +6% of nominal |
| On Battery Voltage Regulation | ±5% RMS |
| Voltage Wave Shape (on battery) | Sine Wave |
| Output Protection | Short circuit protection |
| Battery | |
| Battery Type | Sealed, lead-acid; maintenance free |
| Battery Run time | See Battery Run Times Table |
| Battery Replacement | Hot-swappable internal batteries and external batteries modules |
| Recharge Time | <3 hours to 90% usable capacity |
| Start-On-Battery | Allows start of UPS without utility input |
| General | |
| Diagnostics | Full System self-test on power up |
| UPS Bypass | No Bypass, Internal Bypass |
| Transfer Time | 2-4ms typical |
| Dimensions and Weights | See Model Selection Guide |
| Overload (normal operation) | 110%
overload, shutdown after 3
minutes. 150% overload, shut down 10 cycles |
| Communications | |
| User Interface | Front Control Panel |
| Audible Alarms | For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault |
| Network Transient Protector | UL 497
A, in/out jacks RJ45 (high
voltage models network
protection) & RJ11 (low voltage models modem protection) |
| X-Slot Interface | RS-232
Single Serial Card
(standard), other options available: See available Options Chart |
| Cable | 6-foot communications cable included |
| Power Management Software | Powerware Software Suite CD-ROM (bundled with UPS) |
| Environmental | |
| Safety Certifications | UL; cUL; NOM; C-Tick; CE mark |
| EMC Compliance | FCC Part 15, EN50091-2, Class A for 2.2 KVA and RM; Class B for 1000 and 1500 VA tower models |
| Operating Temperature | 0 to 40º C (32 to 104º F) |
| Storage Temperature | -15 to 50º C (5 to 122º F) |
| Relative Humidity | 0% to 95% non-condensing |
| Lightning & Surge Protection | ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5 |
| Surge Energy Rating | 480 Joules |
| Audible Noise | Less than 40 dBA typical |
| Altitude | 3000m (10,000 ft) without derating |
| Note: Specifications are subject to change without notice due to continuing product improvement programs. | |
|
Model Number1 |
Power Rating (VA/Watt) |
Input/ Output Voltage (Vac)2 |
Input Connection | Output Receptacles4 | Dimensions HxWxD (in/mm) | Weight (lb/kg) |
| Tower Models (North America) | ||||||
| PW5125 1000 |
1000/700 | 120 | 5-15P, 6 ft line cord |
(6) 5-15R | 9.45 x
6.38 x 15.79/ 240 x 162 x 401 |
34.3/15.6 |
| PW5125 1500 |
1440/1050 | 120 | 5-15P, 6 ft line cord |
(6) 5-15R | 9.84 x
6.38 x 18.39/ 250 x 162 x 467 |
50.7/23.0 |
| PW5125 2200 |
1920/1600 | 120 | 5-20P, 6 ft line cord |
(6)
5-15R, (2) 5-20R |
9.84 x
8.07 x 19.41/ 250 x 205 x 493 |
68.3/31.0 |
| PW5125 2200b |
2080/1600 | 208 |
IEC-320-15A, inlet3 |
(9)
IEC-320-10A (C13) |
9.84 x
8.07 x 19.41/ 250 x 205 x 493 |
68.3/31.0 |
| Tower Models (International) | ||||||
| PW5125 1000i |
1000/700 | 230 |
IEC-320-10A, inlet3 |
(6)
IEC-320-10A (C13) |
9.45 x
6.38 x 15.79/ 240 x 162 x 401 |
34.3/15.6 |
| PW5125 1500i |
1500/1050 | 230 |
IEC-320-10A, inlet3 |
(6)
IEC-320-10A (C13) |
9.84 x
6.38 x 18.39/ 250 x 162 x 467 |
50.7/23.0 |
| PW5125 2200i |
2200/1600 | 230 |
IEC-320-10A, inlet3 |
(9)
IEC-320-10A (C13) |
9.84 x
8.07 x 19.41/ 250 x 205 x 493 |
68.3/31.0 |
1. 50/60 automatic frequency
selection.
2. 120 V models are 110 V, 120 V,
127 V user-selectable. 230 V models
are 220 V, 230 V, 240 V
user-selectable. 208 V models are
208 V, 220 V, 230 V, 240 V
user-selectable.
3. Includes (2) each IEC
interconnect cables.
4. 1000-1500 VA models are divided
into (2) Load Segments (receptacle
groups). 2200-3000 VA models are
divided into (3) Load Segments
(receptacle groups). 5000/6000VA
models are divided into (2) Load
Segments.
| VA |
Standard Internal Batteries |
1 EBM | 2 EBMs | 3 EBMs | 4 EBMs |
| Tower Models | |||||
| 1000 | 5/14 | 25/60 | 55/170 | 83/199 | 109/228 |
| 1500 | 6/17 | 33/79 | 63/146 | 92/174 | 120/201 |
| 2200 | 5/14 | 26/60 | 55/170 | 81/198 | 106/224 |
*Up to 4 EBMs can be connected to
1000-2200 VA models. EBM run times
include internal batteries.
Run time chart provides typical
information. Battery run times are
approximate and may vary with
equipment, configuration, battery
age, temperature, etc.
| Order Number | Description |
| 05141562-0091 | 4-post rackmount kit (1000-3000 VA rackmount models) fits 19-inch racks |
| 05146726-5591 | 2-post rackmount kit (1000-3000 VA rackmount models) fits 19-inch racks |
| 05146447-5502 | Multi-server card |
| 05146508-5501 | USB Card |
| 1018460 | Relay Card |
| 116750221-001 | ConnectUPS Web/SNMP card |
| 103002510-5501 | Modbus Card |
| 116750224-001 | Environmental Monitoring Probe (EMP) |
| 05146519-001 | Powerpass Distribution Module (1000/1500 rackmount models only) |
| 05146401-5501 | Power Distribution Unit 250 VA 0U form factor. Side cabinet mount (5000/6000 VA) |
Buy batteries on-line and get it fast!
|
Power Factor Inc. / Batteries ASAP! 2526 Manana Suite 102 Dallas, Texas 75220 800-706-7009 Established 1996 While every precaution has been
taken to ensure accuracy and completeness in this literature, Power Factor Inc.
assumes no responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions. Specifications