Powerware BladeUPS product image

BladeUPS Power System
Features and Benefits

BladeUPS ZC1212200100000 ZC1212210100000 ZC1212600100000 ZC121260100000

ZC1212000100000 ZC1212010100000 ZC121P060100000 ZC121P061100000

The Powerware BladeUPS is a revolutionary power quality solution, expanding power protection from 12 kW to 60 kW in a single industry standard 19-inch rack, and most significantly, providing this robust, compact solution without generating the additional heat associated with legacy end-of-row, modular UPS products. The Powerware BladeUPS is designed to be the most flexible UPS on the market. It can be deployed in a number of configurations from a distributed architecture (one in every rack), to end of row (up to six units in a rack), to a central system (not on the IT floor, but in the electrical closet). In addition, the exceptionally high efficiency rating is not a large energy cost burden when installed inline with the output of a large, central UPS or in highly critical computing areas where dual UPS redundancy (2N) is required.
 

Features and Benefits

  Grows with expanding IT applications using scalable architecture
  Reduces operating expenses with more flexible, compact configuration options than traditional end-of-row solutions
  Extends battery life and optimizes battery recharge time with ABM technology

Product Snapshot

 Power Rating:  12-60 kW
 Input Voltage:  230-400V or 120-208V
 Output Voltage:  230-400V or 120-208V
 Frequency:  50 or 60 Hz
 Backup Times:  Typical 14 minutes at half load; extended battery modules available
Grows with expanding IT applications using scalable architecture
Reduces operating expenses with more flexible, compact configuration options than traditional end-of-row solutions
Extends battery life and optimizes battery recharge time with ABM technology
Conserves valuable rack space with power-dense 6U form factor
Delivers the highest levels of reliability with patented Powerware Hot Sync® paralleling technology
Reduces single point of failure with an intelligent bypass design to eliminate human error
Simplifies service with hot-swappable battery and electronics modules
Easily integrates connectivity products such as the Powerware Power Xpert® Gateway Series 2000 card

Service and Support

On-site installation and integration services
Remote monitoring solutions
Extended warranty and service plans
 
Eaton Logo, links to the Eaton homepage

BladeUPS Power System Technical Specs

General Characteristics

Power Rating 12 kW per UPS Module
Efficiency Up to 97%
Heat Dissipation <371W/1266 BTU/hr. at 100% rated load
Cooling Fan cooled, temperature microprocessor monitored; front air entry, rear exhaust
Audible Noise, Normal Operation 58 dBA at 1 meter
Altitude 1000 meters (3300 ft. ASL)

Input Characteristics

Input Voltage 208 Vac and 400 Vac models
Voltage Range 208V model: 180 to 255 Vac
400V model: 311 to 519 Vac
Frequency Range 50 or 60 Hz, ±5 Hz, auto detecting
Input Current Distortion <5% with IT loads (PFC power supplies)
Input Power Factor >.99 with IT loads (PFC power supplies)
Inrush Current Load dependent
Input Requirements Three-phase, four wire + ground
Bypass Source Same as input, (single feed)
Generator Compatibility Fast sync slew rate for optimum generator operation

Output Characteristics

Rated Output Voltage 208V model: Programmable 180 to 229 Vac, Ph to Ph (standard)
187 to 229Vac ph to jph (ITEC optimized)
400V model: 180 to 240 Vac, Ph to N
Output Configuration Three-phase, four wire + ground
Output Frequency (nominal) 50 or 60 Hz auto-detection on startup
Frequency Regulation 0.1 Hz free running
Load Power Factor Range Lagging: 0.7
Leading: 0.85
Total Output
Voltage Distortion
<3% with IT loads (PFC power supplies)
<5% non-linear or non-PFC power supplies

Battery Characteristics

Battery Type VRLA - AGM
Battery Runtime (Internal) 13.6 minutes at 50% load
4.7 minutes at 100% load
Battery String Voltage 240 Vdc (Internal redundant strings in each module)
Battery Test Automatic battery test standard (remote scheduling capable).
Manual battery test from front display
Battery Recharge Profile ABM Technology. Advanced three-stage charging technique
 
Battery Cut-off Voltage Variable from 1.67 VPC at <5 min. runtime to 1.75 VPC at >90 min. runtime
 
Battery Low Condition Announced with alarm
Battery Load Share  Yes: based on battery voltage during discharge. Load shifted to systems with strongest batteries to give longest runtime for battery condition 
Extended Battery Capability Yes, add up to four additional 3U battery enclosures >34 min at 100% load,
>1 hour at 50% load)

Physical Characteristics

Dimensions (HxWxD)
Installed


Shipped


EBM

10.5 (6U) x 17.4 x 26.0 inches
266 x 438 x 660mm

27 x 39 x 46 inches
686 x 991 x 1168 mm

5.2 (3U) x 17.2 x 26 inches
132 x 437 x 660 mm
Note:
Total Chassis Weight
without batteries or
electronics
Total Chassis Weight
with batteries or
electronics
 

100 lb. (46 kg)


307 lb. (140 kg)
Total UPS Weight without Batteries 135 lb. (61 kg)
Total UPS Weight with Batteries 307 lb. (140 kg)
EBM Weight 170 lb. (77 kg)

Communications and User Interface

Software Compatibility UPS ships with Software Suite CD containing LanSafe
power management software and trial version of PowerVision
X-Slot® Bays Two available for the cards listed below
Optional X-Slot Communication Cards  Application  Powerware Card
 WEB - TCP/IP  ConnectUPS-X Web/SNMP Card
 Modbus® RTU  Modbus Card
 IBM eServer™
(i5™, iSeries™,
or AS/400®)
 
 Relay Interface Card
 N/O, N/C
(dry contacts)
 Industrial Relay Card
 Parallel  Powerware Hot Sync CAN Bridge Card
 Remote Monitoring  Modem card
Power Xpert® Gateway Series 2000 Card   
Control panel LCD Two lines by 20 characters
Four menu-driven interface buttons
Four status at a glance LEDs
Multi Language Standard: English, Spanish, French, German, and Portuguese

Available: Finnish, Norwegian, Swedish, Russian, Hungarian, Polish, Romanian, Czech, Danish, Greek, Turkish, Bulgarian, Korean, and Chinese
Configuration Changes User capable, firmware auto configures.
Online firmware updates available for operational changes
Dry Contact Inputs Two, user configurable
Dry Contact Outputs One, user configurable

Service

Installation User capable, located in the IT racks, operational factory service available
Preventative Maintenance User capable, optional factory service available
Corrective Maintenance User capable, optional factory service available
Serviceability Features Hot-swappable batteries
Hot-swappable electronics module
Automated internal maintenance bypass
Auto-configure firmware
Flash firmware upgradeable

Certifications

Safety 208V model: UL1778, cUL
400V model: CE
EMI 208V model: FCC Part15 Class A
400V model: EN62040-2 Class A
Surge Protection ANSI C62.41, Cat B-3
Hazardous materials (RoHS) Complies per EU Directive 2002/95/EC Category 3 (4 of 5)
Warranty
Standard 12 months from install / 18 months from shipment
Warranty Repair Factory depot repair or replace

Service Support Agreements2

Depot PowerTrust Express
On-site 5x8 PowerTrust Value
On-site 7x24 PowerTrust eight-, six- or two-hour response

Options and Accessories

Detachable input cord
Detachable input/output cord assembly
Detachable paralleling cord assembly
Extended Battery Modules (EBM)
3U output sub-distribution modules (RPM)
0U to 3U rack power strips
60 kW Powerware BladeUPS Parallel bar
Environmental Monitoring Probe (EMP) for temperature and humidity monitoring
X-Slot Communication Cards (see Communications and User Interface above)
Remote monitoring service by Eaton: eNotify; requires purchase of Web Card and Environmental Monitoring Probe 

ABM Technology Hot Sync Technology PW3105 PW5110 PW5115 PW5115 RM PW5125 PW5125 RM PW9120 PW9125 PW9140 PW9155 PW9170+ Ferrups Ferrups RM BladeUPS PW9315 PW9355

UPS Technology Power Problems UPS Systems XPCC Powerware Minute Man Tripp-Lite Emerson Liebert GE Industrial SLA Batteries CSB MK Battery Powersonic Rhino Universal EnerSys Panasonic Power Patrol Big Beam SENS Legacy GS Gates Hawker C&D Dynasty Power Battery Contact Us Links

Up

 

 

Buy batteries on-line and get it fast!

UPS Technology
Power Problems
UPS Systems
XPCC
Powerware
Minute Man
Tripp-Lite
Emerson Liebert
GE Industrial
SLA Batteries
CSB
MK Battery
Powersonic
Rhino
Universal
EnerSys
Panasonic
Power Patrol
Big Beam
SENS
Legacy
GS
Gates Hawker
C&D Dynasty
Power Battery
Contact Us
Links

 

 

 

 

 

 

 

 

 

 

 

 

Home Up UPS Technology Power Problems UPS Systems XPCC Minute Man Tripp-Lite Emerson Liebert GE Industrial SLA Batteries CSB MK Battery Powersonic Rhino Universal EnerSys Panasonic Power Patrol Big Beam SENS Legacy GS Gates Hawker C&D Dynasty Power Battery Contact Us Links

Power Factor Inc. / Batteries ASAP!

2526 Manana Suite 102 Dallas, Texas 75220

800-706-7009

Established 1996

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.