Endeavor 6kvA Rack On-Line UPS
Minuteman® 6kVA On-line Rackmount UPS
Applications
6kVA On-line UPS Features
Options
Endeavor 6kVA true on-line rack mount upsMAIN CONTROL MODULE - ED6200RMThe Main Control module takes only 2U in rack height and provides 208/240V input and output. Input is hardwired to the unit. The main control module has a LCD/LED display. Each control module must have at least one battery back (EDBP6000RM). Parallel functions are available for up to 208V 24kVA. N+1 full-redundancy function is available up to 18kVA for 208/240V applications and 6kVA for 120V applications. Optional receptacle boxes are available for 6kVA units. TRANSFORMER MODULE - ED6000RMXFMRThe transformer module steps down the 208/240V input to 120/208/240V output, takes 2U in rack height, and requires a control module (ED6200RM), and Battery Pack (EDBP6000RM) to work. It has an internal bypass switch for single 6kVA installations (Not available on parallel installations). It handles 208/240V input and 120/208/240V output. BATTERY PACK MODULE - EDBP6000RMEach battery pack module (EDBP6000RM) occupies 3U in rack height and requires a control module (ED6200RM) to operate. Multiple battery packs can be daisy chained. Only one receptacle box can be attached to a battery pack module. Battery packs are charged through the main UPS. PARALLEL CONFIGURATIONSIn addition to a stand-alone configuration, the Endeavor 6kVA rackmount UPS can be configured as:
NOTE: 120V output from the Endeavor 6kVA rackmount UPS is available only in a 6kVA stand-alone configuration or a Parallel for Redundancy (N+1) 6kVA 208V/240V input and 6kVA 120V output made up of two ED6200RM control units, two EDBP6000RM battery packs and two ED6000RMXFMR transformers. PARALLEL FOR CAPACITY CONFIGURATIONSThis configuration uses mirrored Endeavor 6kVA rackmount UPS system to achieve higher than 6kVA loads. Currently, parallel capacity configurations can be used to accommodate output loads of 12, 18, and 24kVA for 208V/240V systems. Parallel for Capacity Configuration Table
REDUNDANCY (N+1) CONFIGURATIONSThis configuration is used to provide redundancy backup. When one UPS is taken offline, this configuration allows the load to be redistributed to the remaining UPS units.
Redundancy (N+1) Configuration Table
OPTIONAL RECEPTACLE BOXESTwo receptacle boxes are available. One for 208V/240V output only (ED6-208RB) and one for both 120V and 208V/240V output (ED6-120RB). 208V-Only Receptacle Box- ED6-208RBReceptacles: (1) L6-30R, (1) L6-20R and (4) 6-15/20R. Only one receptacle box can be connected to a battery pack.
120V/208V Receptacle Box - ED6-120RBReceptacles: (1) L6-30R, (1) L5-30R, (1) L5-20R and (2) 5-15/20R. Only one receptacle box can be connected to a battery pack.
COMMUNICATION AND SOFTWAREThe Endeavor 6kVA UPS currently uses the NetAgent SNMP card and includes software for monitoring the UPS. A new version of the ED6200RM with SentryPlus/SNMP-NET communications capability will be available in 2008. Both versions are compatible with Minuteman’s new SentryGold Enterprise Software which permits the monitoring and control of Minuteman UPS and Power Distribution Units. BATTERIESThe Endeavor 6kVA UPS uses a battery pack (EDBP6000RM) that contains sealed, non-spillable, maintenance free, value regulated, lead acid batteries. The UPS module does not have internal batteries. Typical recharge time for the battery pack is 8 hours from total discharge. The battery pack contains (20) 12V 7.2Ah batteries. Runtime at full load is 9 minutes. At half load the runtime is 23 minutes WHAT THE FUTURE HOLDS...Parallel Configurations: All current 6kVA products are compliant with parallel configurations when these options are available. In the relatively near future you will be able to configure your Minuteman Endeavor 6kVA into a parallel configuration increasing system capacity up to 24kVA.
ENDEAVOR 6KVA UPS LED/LCD FRONT PANEL DISPLAY/CONTROLThe Endeavor 6kVA UPS multi-functional LCD/LED panel will display various states of the UPS. The LED display will show the UPS working status, Utility Status and UPS Abnormal status. The LCD display will show the Input/Output voltage, frequency, load status, internal temperature, and faults. Configuring the UPS parameters are done through the LCD. MAINTENANCE BYPASS SWITCH
OPTIONS
|
Buy batteries on-line and get it fast!
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Power Factor Inc. / Batteries ASAP! 2526 Manana Suite 102 Dallas, Texas 75220 800-706-7009 Established 1996 While every precaution has been
taken to ensure accuracy and completeness in this literature, Power Factor Inc.
assumes no responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions. Specifications
subject to change without notice. |