Power Factor Inc.  -   800-706-7009

www.powerfactorincdirect.com

Back Home Up Next

 

Find the battery you want at the right price @ batteries asap!

Home
CSB Battery Cautions
GP Series Features
GP Series Technical
GP645
GP672
GP6120
GP1222
GP1245
GP1272
GP12120
GP12170
GP12220
GP12260
GP12340
GP12400
GP12650
GP121000
EVX Series Features
EVX Series Technical
EVX1272
EVX12120
EVX12170
EVX12200
EVX12260
EVX12300
EVX12340
EVX12400
EVX12520
EVX12650
EVX12750
EVX121000
HC Series Features
HC Series Technical
HC1217W
HC1221W
HC1225W
HC1228W
HR Series Features
HR Series Technical
HR1221W
HR1224WF2F1
HR1234WF2
HR1251WF2
HR1290W
HR12120WFR

Home

 

 

 

 

HC1225W is manufactured by CSB (China Storage Battery). The CSB HC1225W is a 12 Volt 25 Watt per cell sealed lead acid rechargeable battery.

Contact us at 800-706-7009 to purchase this battery

HC1225W

12 V 25.0w/cell
HC1225W is specially designed for high efficiency discharge application. Its invisible terminal can be inserted PC board directly. HC series battery can serve more than 260 cycles at 100% discharge in cycle service and up to 5 years in standby service.
 
Download : HC1225 Spec Sheet-(619.19K)
 
 
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 25W @ 15 minute-rate to 1.67V per cell @ 25°C (77°F)
Weight Approx. 2.25kg. (4.96 lbs.)
Maximum Discharge current 60A (5sec.)
Internal Resistance Approx. Approx. 30mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 2.5A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal C1-Faston Tab187/250
Container Material ABS(UL94-HB/File E50263)*Flammability resistance of(UL94-V0/File E88367) can be available upon request.

 
Dimensions  


 
Constant Current Discharge Characteristics Unit:Amperes (25℃,77℉)
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 47.83 35.25 28.25 23.00 19.27 14.25 11.92 9.08 5.28 3.21
1.67V 45.05 33.70 26.90 21.96 18.57 13.89 11.70 8.95 5.21 3.10
1.70V 42.50 32.14 25.68 20.89 17.81 13.48 11.47 8.80 5.15 2.96
1.75V 40.04 30.58 24.46 19.88 17.02 13.09 11.24 8.66 5.08 2.83
1.80V 37.58 28.75 23.00 18.87 16.24 12.73 10.99 8.50 5.03 2.68
1.85V 35.12 26.91 21.54 17.84 15.52 12.33 10.71 8.33 4.97 2.52

 

Constant Power Discharge Characteristics Unit:Watts (25℃,77℉)
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 574.00 423.00 339.00 276.00 231.73 171.79 143.00 109.00 63.40 38.50
1.67V 542.20 404.80 323.00 264.60 223.40 166.40 140.70 107.30 62.66 37.07
1.70V 510.00 386.10 307.60 253.00 214.30 161.20 138.00 105.50 62.00 35.50
1.75V 480.50 365.10 291.50 240.00 204.50 156.67 134.90 104.00 61.22 34.00
1.80V 451.00 345.00 275.60 227.00 195.10 151.00 132.00 102.00 60.40 32.10
1.85V 421.50 323.00 258.50 214.00 185.78 145.88 128.50 100.00 59.70 30.20

The HC1225W should replace the following part numbers for most applications, be sure to check dimensions, terminal size, voltage and amp hour ratings.

  B & B Battery BP6512RT
  B & B Battery BP712RT
  CSB Battery HC1225W
  CSB Battery HC1228W
  Interstate Batteries ASLA1028
  Medical Data ESCORT PRISM 20412
  Medical Data ESCORT PRISM 20413
  Medical Data ESCORT PRISM 20414
  Medical Data ESCORT PRISM SE
  R&D 5045
  Universal Power Group D2831

Typical applications for the HC1225W include:

Cycle Use

  • Portable VCR/TV, tape recorders, radios and so on

  • Power tools, lawn mowers, vacuum cleaners

  • Cameras and photographic equipment

  • Portable personal computers, word processors, portable terminals, and so on

  • Portable measuring equipment

  • Portable telephone sets

  • Various power toys and hobby equipment

  • Lighting equipment

Standby Use

  • Communications and electric equipment

  • Emergency lighting equipment

  • Fire alarms and security systems

  • Various telemeter equipment

  • Office computers, microcomputers, and other office automation equipment

  • Robots, control equipment, and other factory automation equipment

  • UPS power supply

  • Emergency power supply in power generation plants and substations.

Solar Cell Power Generation

  • Water pumping systems

  • Portable power supplies

  • Small town power systems

 

Buy batteries on-line and get it fast!

UPS Technology
Power Problems
UPS Systems
XPCC
Powerware
Minute Man
Tripp-Lite
Emerson Liebert
GE Industrial
SLA Batteries
CSB
MK Battery
Powersonic
Rhino
Universal
EnerSys
Panasonic
Power Patrol
Big Beam
SENS
Legacy
GS
Gates Hawker
C&D Dynasty
Power Battery
Contact Us
Links

 

 

 

 

 

 

 

 

 

 

 

 

Home Up UPS Technology Power Problems UPS Systems XPCC Powerware Minute Man Tripp-Lite Emerson Liebert GE Industrial SLA Batteries MK Battery Powersonic Rhino Universal EnerSys Panasonic Power Patrol Big Beam SENS Legacy GS Gates Hawker C&D Dynasty Power Battery Contact Us Links

Power Factor Inc. / Batteries ASAP!

2526 Manana Suite 102 Dallas, Texas 75220

800-706-7009

Established 1996

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.